Behaviuor of insulated metal decking under shear load. by D. Lapin

Cover of: Behaviuor of insulated metal decking under shear load. | D. Lapin

Published by University of Salford in Salford .

Written in English

Read online

Edition Notes

MSc thesis, Civil Engineering.

Book details

ID Numbers
Open LibraryOL20904473M

Download Behaviuor of insulated metal decking under shear load.

Insulated Concrete Floors & Roofs reduce utility bills and HVAC sizes and create a comfortable & healthy indoor environment all year round. Ideal for Radiant Heating. INSUL-DECK’s lighter structure eliminates % of the mass & shoring. Utility chases and steel furring strips are built-in.

This paper investigates the behavior of composite metal deck slabs under repeating impact loading. The shear bearing capacity between the concrete slab and metal deck was provided by the embossments on the metal deck.

The study is carried out in two parts; laboratory tests and the numerical by: 1. The shear connection is formed by the concrete which is passing through some or all of the web openings, depending on the configuration of the metal deck (shallow or deep), is similar to the shear connection used in the iTECH beam and Deltabeam and different from the shear connection used in slim-floor by: Behaviuor of insulated metal decking under shear load.

book It shows that (1) the slip at the steel-UHPC interface is relatively small (less than mm) before the composite beam achieves its yielding load, and after achieving the yielding load carrying capacity the slip increases faster; (2) at the same loading level, the slip at the middle of shear span (i.e., slip measured by DH2 as shown in Fig.

7a Cited by: 3. The results show that the shear failure test results of glazed hollow bead insulation concrete beams are similar to those of ordinary concrete beams; the shear bearing capacity of vitrified microbeads thermal insulation concrete beams is ∼13% higher than that of ordinary concrete beams under the same conditions, and stiffness degradation is Cited by: 2.

Dimensionless load-inelastic displacement curves for large beams (D = mm) and intermediate steel ratio (ρ = %). (a) Ribbed wires; the grey shaded band is the experimental range, the thick full line the theoretical prediction for the mean values of the parameters, and the hatched band corresponds to the standard deviation in τ c.

The behavior of steel structures is an intricate and fascinating topic. This module is intended to serve as a guide to the AASHTO Load and Resistance Factor Design (LRFD) Specifications and their representation of the behavior of steel bridge systems and members.

The module focuses on the structural form and function of bridge systems and. Steel Decking. Steel decking is used in many applications, but is particularly well suited to roofing and flooring. Vulcraft manufactures many different types of deck, including roof deck, floor deck, composite floor deck and cellular deck.

A full line of deck accessories, such as end closure and pour stop, is also available from Vulcraft. • The wheel load of rolling equipment on the steel deck during roofing material installation. • The large spacing between attachments of roofing material to steel deck Behaviuor of insulated metal decking under shear load.

book uplift conditions. • The footprint of a concentrated load on a slab. Concentrated loads shall be analyzed to ensure they do not overstress the steel deck or the. In order for the steel roof framing to deflect without applying load to the top of the wall panels, a 2-inch gap was created between the top of the wall panels and the bottom of the roof panels.

This gap was then filled with compressible foam to complete the building envelope (Figures 3 and 4). STEEL: ASTM A36, Fy = 36 ksi for Structural Steel ASTM A, Gr, 40 for #3 & 4, Gr for # 5 and larger rebar steel Insulation = psf D.L = 19 psf Total Load = 35 psf EXTERNAL WALL Dead Load 2x stud wall = psf equal to 50 percent of the unit shear due to diaphragm ac-tion.

The load shall be assumed as acting normal to the. Failure of buckling instability will most likely occur before the displacement reaches the allowable value of the code when a tanker burns under the steel bridge.

This research focuses on critical buckling stress of bridge under fire hazard and a thermal analysis model of a steel bridge is established by FDS (Fire Dynamics Simulator). Thermal parameters of the steel are determined by the. Four standard types: B deck, F deck, N deck, and A deck, in /2” to 3” depths and a variety of panel widths, gauges, and finishes.

Installed directly over structural steel, corrugated steel roof deck serves as the structural substrate in roof construction and provides a solid work surface for the installation of insulation, weatherproofing, and roofing materials. Hello all, So I have a point load on a metal deck with concerete.

I will definately check punching shear but I wanted to check if bending was ok. I have attached a calculation showing what I did to find the bending capacity.

4 DESIGN OF DECKING AND SLABS 15 Steel decking 15 Composite slabs 26 Acoustic insulation 48 Health & Safety 51 Further reading 52 5 DESIGN OF COMPOSITE BEAMS 54 Construction stage 55 Composite stage 56 Shear connection 63 Further reading 72 6 CONSTRUCTION PRACTICE - CONCRETE § Mezzanine slab and deck dead load = 69 psf § Weight of wall panels = 75 psf Roof dead load includes roofing, insulation, metal roof deck, purlins, mechanical and electrical equipment that portion of the main frames that is tributary to the roof under lateral load.

For determination of the. The International Building Code references ANSI/SDI RD and the Steel Deck Institute – Diaphragm Design Manual (DDM) for design of steel deck diaphragms.

Specifically, section of the SDI DDM 3 rd edition presents equations for design of deck connections under the combined effect of tension and shear. These equations were developed from. An experimental study was conducted on reinforced and steel fibre–reinforced concrete composite slabs with steel decking under negative bending moment to quantify the ultimate behaviour, loading.

The results showed that fibers notably improved the in-plane shear behavior (strength and ductility) of the composite slabs.

Steel mesh of size A, synthetic macrofibers at a dosage rate of kg / m 3, and steel fibers at a dosage rate of 15 kg / m 3 all provided comparable in-plane shear capacity and ductility. Therefore, they can be. The flexural and shear rigidities of FRP composite deck panels were calculated.

The response of all panels under service load, factored load, cyclic loading, and the mode of failure were reported. The tested bridge deck panels satisfied the performance criteria.

The safety factor against failure varies from 3 to 8. Composite action by the strength criterion reduced from 47 to 3% as axial load increased from to kN; while that by the stiffness criterion was much lower, 8–%.

Relative to a similar steel-reinforced wall panel with the same reinforcement ratio, the tested walls were 60–89% the strength; and the percentage increased with axial load. Strength and behavior of cold-rolled steel-deck-reinforced concrete floor slabs Reinhold Michael Schuster Vj Transverse shear carried by steel deck at ultimate load of shear-bond failure V, Transverse calculated design shear per foot of width under service conditions.

Steel decks for composite deck-reinforced floor construc­. between the composite steel deck floor slab and the support beams by attaching studs or similar shear devices (see Fig. Steel deck profiles generally are classified as two types, namely cellular and non-cellular deck (see Fig.

Cellular decks differ. increase arrive at 60 the percent. The end slip between the steel deck and the concrete that the ultimate are valuable down the percent when compare with normal composite steel deck floor and increase quality. ค าส าคัญ: Composite steel deck floor, Steel Deck, Longitudinal shear, Perfobond Rib shear connector.

บทน า. An external-insulated cold-formed steel (CFS) wall is a potential configuration that overcomes the disadvantage of cavity insulation in the fire performance of such walls and can meet the sound.

deck, exterior and interior load-bearing walls, beams, girders, posts, and floor framing. Shear walls (or steel moment frames in homes with large windows or other large openings) provide the strength to resist lateral loads. The integrity of the overall building depends not only upon the strength of these components, but also.

Material and Design - Steel roof deck shall be United Steel deck B, F, N, J, H or LS profiles as manufactured by cMc Joist & deck and shall be made from steel conforming to ASTM Designations A SS 40, 50 or 80 (for painted deck) or A Gr 50 or 80 (for galvanized deck). The minimum yield strength is 40, psi.

Point Loads on Composite Deck-Reinforced Slabs. The behavior of composite deck-reinforced floor systems under concentrated loads is described.

Laboratory experiments show that these floor systems may have a considerably larger capacity to support concentrated loads than indicated by existing design techniques. There are two sources of this additional strength. Released on J The app offers optimized steel deck design solutions based on cost or labor for a given shear and uplift.

It makes calculations for any solution generated and produces a submittal package that includes fastener information, code reports, Factory Mutual reports, Appendix VII of DDM03, coating information and tools for installation. of steel deck under various conditions of fastener arrangement, purlin Wide Rib.

__l ~TI. spacing, gage, and material yield strength. the investigation reported herein, the three types of deck tested were: narrow.

rib, known in the trade as "A" deck, wide rib, or. deck, and intermediate rib deck. Roof Deck –Transverse Distribution 14 L = Span X = % of Span Based on 1 ½” Deck For X ≤ be= B + 6 ≥ 12 For load footprint width transverse to the deck span.

When the load centroid is not at the center of the footprint, let B equal twice the. Behaviour of a one-bay frame during an earthquake No matter how well designed a structure is, one or possibly more structural members will exceed their design strength, either because seismic forces might exceed the design assumptions or because of local conditions during the construction.

With FormLok ® dovetail deck's superior sound ratings, you can easily find a floor finish that meets code and fits your version.

For steel deck slabs that have end-span studs, two types of com­ posite behavior need to be considered. A general view of such a floor slab system with both composite deck and studs is shown in Fig.

Past research on composite steel deck slabs has not considered the effect of stud end restraint on shear-bond behavior. Also, past. Punching shear behavior of steel-concrete composite decks with different shear connectors *Xiao-Qing Xu1) and Yu-Qing Liu2) 1), 2) Department of Bridge Engineering, Tongji University, ShanghaiChina 1) @; 2)[email protected] ABSTRACT The ultimate strength of composite deck is frequently governed by the punching.

ROOF DECK: Metal roof deck can be specified as either Type B or N. Type B has 1 ½” high ribs while Type N has 3” high ribs and can span up to 17 feet. In our experience, we recommend galvanizing all roof deck with at least a G60 or G90 level depending on its exposure and use.

There are 3 types of metal decking: –Form Decking: Permanent formwork for reinforced concrete slab until slab can support itself and the live load. 3 common rib depths. 9/16″ (′-3′ span) 1″ (3′ – 5′ span) 2″ (5′ – 12′ span) –Composite Decking: Serves as tensile reinforcement for the concrete ite action occurs between slab and beams/joists below.

plane shear strength and stiffness is predictable. The principal elements determining these factors include spacing of the support framing, the size and thickness of the individual deck panels and the interconnecting fasteners. A metal roof deck diaphragm is a fairly flexible system. – 50mm Dovetail rib profile maximising steel deck bond to concrete – Minimum slab depth of mm – Spans up to m unpropped – Gauge range available up to mm – Shear keys on flange and webs of ribs gives class leading load capability – 1hr fire performance with mm slab depth – Fire performance up to 4hrs – Acoustic.

AMERICAN NATIONAL STANDARDS INSTITUTE/ STEEL DECK INSTITUTE STEEL DECK s INSTITUTE ® 5 5 C. All sheet steel used for deck or accessories that carry defined loads shall have a minimum specified yield stress that meets or exceeds 33 ksi ( Mpa).

1 For the case where the steel deck acts as a form, design yield and tensile. Shear connectors on the top flanges of the steel girders provide the means to achieve composite action between the slab and the girders, thus increasing both stiffness and strength. This article reviews the behaviour of the connectors and the design rules for the shear connection in BS EN Vulcraft provides a number of resources to help you efficiently and successfully specify steel joists and deck.

Our latest catalogs are listed below. Each catalog can be viewed online, downloaded or ordered where you will receive a hard copy in a few days.

The test parameters investigated were (1) reinforcement type (BFRP and steel); (2) BFRP bar size (12 and 16 mm); (3) reinforcement ratio in each direction (–%); and (4) edge-restraining [restrained or unrestrained (free)].The slabs were tested up to failure over a center-to-center span of 2, mm under a single concentrated load acting.